MILPRF50884F
APPENDIX A
A.4.8.5 Electrical inspection.
A.4.8.5.1 Continuity and circuit shorts.
A.4.8.5.1.1 Production screening. Printed wiring boards shall be electrically tested using either automatic or
manual equipment capable of verifying the test level C requirements of IPC9252 for 100 percent continuity and
isolation.
A.4.8.5.1.2 Qualification and referee testing.
A.4.8.5.1.2.1 Circuit continuity (see A.3.7.5.1.1). A current shall be passed through each net by applying
electrodes on the terminals at each end of the net. The current passed through the net shall not exceed those
specified in the applicable design standard (see A.3.1.1 and appendix D) for the smallest conductor in the circuit. For
manual testing during qualification, the current shall be 1.0 amp minimum and shall be applied for a minimum of 5
seconds.
A.4.8.5.1.2.2 Circuit shorts (isolation resistance) (see A.3.7.5.1.2). A test voltage shall be applied between each
net and all other nets that are adjacent to the net under test. The voltage shall be applied between nets of each layer
and the electrically isolated net of each adjacent layer. For manual testing the voltage shall be 200 volts minimum
and shall be applied for a minimum of 5 seconds. When automated test equipment is used, the minimum applied test
voltage shall be as specified on the applicable master drawing. If a test voltage of the printed wiring board is not
specified on the applicable master drawing, the test voltage shall be the maximum rated voltage of the net being
tested. If no maximum rated voltage is specified, or it is less than 40 volts, then the minimum test voltage shall be 40
volts minimum.
A.4.8.5.2 Circuit or plated-through hole short to metal core substrate (see A.3.7.5.2). A polarizing voltage of 500
volts shall be applied between conductors and or lands and the metal core substrate in a manner such that each
conductor and or land is tested to the conditions of A.4.8.5.1.2.2.
A.4.8.5.3 Dielectric withstanding voltage (see A.3.7.5.3). The printed wiring board test specimen shall be tested in
accordance with test condition B of test method number 2.5.7 of IPCTM650. The following details and exceptions
apply:
a.
Test specimen: The printed wiring board test specimen shall be as identified in table AVIII.
b.
Magnitude of test voltage: Condition B (1,000 V dc +25 V dc, 0 V dc).
c.
Duration of application of test voltage: 30 seconds +3, 0 seconds.
d.
Points of application: The dielectric withstanding voltage shall be applied between all common portions of
each conductor pattern and all adjacent common portions of each conductor pattern. The voltage shall be
applied between conductor patterns of each layer and the electrically isolated pattern of each adjacent layer.
A.4.8.5.4 Impedance testing (see A.3.7.5.4). Impedance testing shall address the parameters required by the
level C requirements of IPC9252.