MILPRF55110G
APPENDIX E
An example of the calculation is as follows:
H
= See table EI for the values for H.
R1
= Plated-through hole radius = .018 inches nominal (0.046 cm).
R2
= O-ring internal radius = 0.075 cm.
Area = (2)(š)(0.046)(H) + [(2)(š)(0.075)2 (2)(š)(0.046)2]
= (0.22890)(H)
+ [0.03534 0.013295]
= 0.2890 cm (H cm) + [0.022045 cm2]
table E-I TABLE EI
TABLE EI. SERA plated-through hole example calculation data.
Printed wiring board thickness
H
Area
(centimeters2)
(inches)
(centimeters)
0.0367
0.0508
.020
0.0441
0.0762
.030
0.0514
0.1016
.040
0.0587
0.1270
.050
0.0661
0.1524
.060
0.0734
0.1778
.070
0.0808
0.2032
.080
0.0881
0.2286
.090
0.0955
0.2540
.100
0.1028
0.2794
.110
E.5.4
E.5.4 Evaluation of test data. The change in reduction voltage shall be plotted versus the charge density (current
density x time). This SERA curve generated shall be differentiated and then incorporate the following moving window
average, curve smoothing function:
V(n) = SUM [V(n5) through V(n+5)] / 11
The following eight SERA parameters shall be calculated from the differentiated and smoothed SERA curve using the
following threshold limits listed below. Figure E2 illustrates these parameters and threshold limits on an example
SERA curve.
1.
Voc = The final open circuit voltage measured for the SERA differentiated/smoothed curve.
2.
Q1 = The area under the curve defined by: Nmin1 threshold value (defined constant value).
3.
V2 = The voltage on the differentiated/smoothed curve defined by: (Nmin3 + Nmin1 threshold values) / 2.
4.
Q2 = The area under the curve defined by: Nmin3 threshold value Nmin 1 threshold value.
5.
V3 = The voltage on the differentiated/smoothed curve defined by: (Nmin5 + Nmin3 threshold value)/2.
6.
Q3 = The area under the curve defined by: Nmin5 threshold value Nmin3 threshold value.
72
For Parts Inquires submit RFQ to Parts Hangar, Inc.