MIL-DTL-62741A(AT)
4.2 Verification methods. The types of verification methods included in this section are
visual inspection, measurement, sample tests, full-scale demonstration tests, simulation, modeling,
engineering evaluation, component properties analysis, and similarity to previously-approved or
previously-qualified designs.
4.2.1 Verification alternatives. The manufacturer may propose alternative test methods,
techniques, or equipment, including the application of statistical process control, tool control, or
cost-effective sampling procedures, to verify performance. See the contract for alternatives that
replace verifications required by this specification.
TABLE VII. Verification methods.
Title
Requirement
Verification
4.2
Design, materials & manufacturing
3.2
processes
Operating requirements
4.2.3
3.3
Input power
3.3.1
4.2.3.1
4.2.3.2
Logic levels
3.3.2
3.3.3.1
4.2.3.3.1
Output clocks
4.2.3.3.2
Output latches
3.3.3.2
3.3.3.3
4.2.3.3.3
Voltage level shifters
4.2.3.3.4
Input clocks
3.3.3.4
3.3.3.5
4.2.3.3.5
Input buffers
4.2.3.4
3.3.4
Internal logic levels
4.2.3.5
3.3.5
Input channel max. select
4.2.3.6
3.3.6
Input channel attenuation
4.2.3.7.1
3.3.7.1
Instrumentation amplifier
3.3.7.2
4.2.3.7.2
Summing amplifier
3.3.7.3
4.2.3.7.3
Gain select & accuracy
3.3.74
4.2.3.7.4
Filter select & attenuation
4.2.3.8
3.3.8
ADCON
4.2.3.9
3.3.9
ATE test 1/
4.2.4
Interface requirements
3.4
3.4.1
4.2.4.1
PWA overall envelope
Ownership & support requirements
3.5
4.2.5
Interchangeability
3.5.1
4.2.5.1
Identification marking
3.5.2
4.2.5.2
Operating environment requirements
3.6
4.2.6
Temperature
3.6.1
4.2.6.1
Fungus
3.6.2
4.2.6.2
Shock
3.6.3
4.2.6.3
Vibration
3.6.4
4.2.6.4
1/ Not required unless specified (see 6.2).