C = 0 (ZERO DEFECT) SAMPLING, TEST EQUIPMENT, AND INSPECTION FACILITIES
C.1
C.1. SCOPE
C.1.1
C.1.1 Scope. This appendix details the statistical sampling procedures to be used with the QPL product
assurance level of this specification. It also details requirements and procedures pertaining to test equipment and
inspection facilities. This appendix is a mandatory part of the specification. The information contained herein is
intended for compliance.
C.2
C.2. APPLICABLE DOCUMENTS
C.2.1
C.2.1 General. The documents listed in this section are specified in sections C.3, C.4, or C.5 of this specification.
This section does not include documents cited in other sections of this specification or recommended for additional
information or as examples. While every effort has been made to ensure the completeness of this list, document
users are cautioned that they must meet all specified requirements of documents cited in sections C.3, C.4, or C.5 of
this specification, whether or not they are listed.
C.2.2 NCSL Z540-1
C.2.2 Non-Government publications. The following documents form a part of this document to the extent specified
herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.
NCSL INTERNATIONAL (NCSL)
NCSL Z540-1
Calibration Laboratories and Measuring and Test Equipment, General Requirements for.
(Application for copies should be addressed to the NCSL International, 2995 Wilderness Place, Suite 107, Boulder,
CO 803015404 or at URL https://www.ncsli.org.)
(Non-Government standards and other publications are normally available from the organizations that prepare or
distribute the documents. These documents also may be available in or through libraries or other informational
services.)
C.2.3
C.2.3 Order of precedence. In the event of a conflict between the text of this document and the references cited
herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws
and regulations unless a specific exemption has been obtained.
C.3
C.3. DEFINITIONS AND SYMBOLS FOR C = 0 SAMPLING
C.3.1
C.3.1 Definitions. The following definitions shall apply for all statistical sampling procedures:
a.
C = 0 sample plan: The C = 0 sample plans are defined as a combination of a test specimen usage
identifier (see C.3.1.b) and a sample size series (see C.3.1.c). The resulting C = 0 sample plan will be a
two character designator combination that identifies the sample size series that is to be with a type of test
specimen for a particular verification (see C.4.5).
Test specimen usage identifier (see C.4.5 for examples): The following usage modifiers are used to
b.
differentiate when a particular plan is to be used for a particular test specimen:
(1)
The letter "B" will be used to signify that production printed boards are to be sampled.
(2)
The letter "T" will be used to signify that test coupons are to be sampled based on the number of
panels in the lot.
(3)
An asterisk "*" will be used for either printed boards or test coupons.
57
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business