MIL-DTL-62739A(AT)
4.2.3.6 ATE test. To determine conformance to 3.3.6, install PWA into TACOM
approved fixture, on TACOM approved, ATE equipment with TACOM approved software and
instructions.
4.2.4 Interface requirements verification.
4.2.4.1 Overall envelope. Insert the PWA into the present existing location of the test
set, verify its envelope and interfacing conformance.
4.2.5 Ownership and support requirements verification.
4.2.5.1 Interchangeability inspection. To determine conformance to 3.5.1, the
interchangeability between different parts, subassemblies, and assemblies having the same military
part number shall be verified.
4.2.5.2 Identification marking inspection. Verify the presence of the required PWA
identification marking.
4.2.6 Operating environment requirements verification. The electrical performance tests
specified in 4.2.3.1 through 4.2.3.5.3 shall be conducted prior to and at the completion of each
environmental test. Verification of performance during the high temperature and low temperature
environmental test shall be demonstrated by the tests specified in 4.2.3.3, 4.2.3.4, and 4.2.3.5.
4.2.6.1 Temperature. To determine conformance to 3.6.1, the PWA shall be tested as
follows.
4.2.6.1.1 High temperature (operating). To determine conformance to 3.6.1.1, the PWA
shall be subjected to high temperature test in accordance with method 501.3, procedure II (hot
category) of MIL-STD-810, or equivalent (see 4.2.1), and tested to 4.2.3.1 thru 4.2.3.6.
4.2.6.1.2 Low temperature (operating). To determine conformance to 3.6.1.2, the PWA
shall be subjected to low temperature test in accordance with method 502.3, procedure II of
MIL-STD-810, or equivalent (see 4.2.1), and tested to 4.2.3.1 thru 4.2.3.6.
4.2.6.1.3 High temperature (nonoperating). To determine conformance to 3.6.1.3, the
PWA shall be subjected to high temperature test in accordance with method 501.3, procedure I of
MIL-STD-810, or equivalent (see 4.2.1).
4.2.6.1.4 Low temperature (nonoperating). To determine conformance to 3.6.1.4, the
PWA shall be subjected to low temperature test in accordance with method 502.3, procedure I of
MIL-STD-810, or equivalent (see 4.2.1).