MILPRF55110G
APPENDIX A
c.
Thermal stress (see A.3.7.4.8).
(1) Type 1: The number of test coupons to be tested and inspected shall be based on a statistical sample
(2) Type 2: The number of test coupons to be tested and microsectioned shall be based on a statistical
(3) Type 3: A minimum of two test coupons (one A and one B) per panel shall be microsectioned and
inspected. One of the test coupons shall be microsectioned in the panel's length direction and the other
shall be microsectioned along the panel's width direction.
A.4.6.2.2.d
d. Registration (method II, type 3 only): When method II is to be used, registration shall be evaluated using any
combination of two microsectioned test specimens taken from diagonal corners of the panel. Both test
coupons shall have been microsectioned in the vertical plane with one test coupon representing the panel's
length (X) direction and the other representing the panel's width (Y) direction. Test coupons from the "as
NOTE: Concerning type 3 "as received" and "thermal stress" microsections, a minimum of two test coupons (one A
and one B) per panel shall be microsectioned. One of the test coupons shall be microsectioned in the panel's length
direction and the other shall be microsectioned along the panel's width direction. One of the test coupons shall
represent the "as received" condition and the other the after "thermal stress" condition.
A.4.6.2.3
A.4.6.2.3 Rejected lots. If an inspection lot is rejected, the manufacturer may rework it to correct the defects and
resubmit the lot for reinspection, or screen out the defective units (if possible). Resubmitted lots shall be inspected
using tightened inspection (see appendix C). Such lots (reworked or screened) shall be clearly identified as
reinspected lots. Products which have failed any group A inspection herein and have not been reworked and have
not passed reinspection (as specified in this appendix) may not be delivered as compliant printed wiring boards.
A.4.6.2.4
A.4.6.2.4 Disposition of sample units. Sample printed wiring boards which have passed all of group A inspection
herein may be delivered if the inspection lot is accepted.