MILPRF55110G
APPENDIX A
A.4.8.4.7.1
A.4.8.4.7.1 Test specimens. The specimen shall consist of conductors that provide a minimum test length of 2
inches (50.8 mm) and a conductor width of .125 inch (3.3 mm). NOTE: This test coupon is described in the default
design standard (test coupon "N") or number 5.8.3 of IPC-TM-650. At least one test coupon per foil laminated side
shall be placed on the production panel where space is available.
A.4.8.4.8
A.4.8.4.8 Thermal stress (see A.3.7.4.8).
A.4.8.4.8.1
A.4.8.4.8.1 Type 1 (see A.3.7.4.8.1). The printed wiring board test specimen shall be tested in accordance with
test method number 2.6.8 of IPC-TM-650 except that post evaluation microsectioning is not required.
A.4.8.4.8.2
A.4.8.4.8.2 Types 2 and 3 (see A.3.7.4.8.2). The printed wiring board test specimen shall be tested in accordance
with test method number 2.6.8 of IPC-TM-650. The following details shall apply.
a.
Test specimens constructed of thermoset resin base materials shall be subjected to test condition A.
b.
Test specimens constructed of aramid reinforced thermoset resin base materials shall be subjected to test
condition B. Test specimens constructed of thermoplastic resin base materials shall be subjected to test
condition C.
A.4.8.5
A.4.8.5 Electrical inspection.
A.4.8.5.1
A.4.8.5.1 Circuit continuity (see A.3.7.5.1). A current shall be passed through each net by applying electrodes on
the terminals at each end of the net. The current passed through the net shall not exceed those specified in the
applicable design standard (see A.3.1.1 and appendix D) for the smallest conductor in the circuit. See IPC-9252 for
additional guidelines.
A.4.8.5.2
A.4.8.5.2 Circuit shorts (isolation resistance) (see A.3.7.5.2). A test voltage shall be applied between each net and
all other nets that are adjacent to the net under test. The voltage shall be applied between nets of each layer and the
electrically isolated net of each adjacent layer. For manual testing, the voltage shall be 200 volts minimum and shall
be applied for a minimum of 5 seconds. When automated test equipment is used, the minimum applied test voltage
shall be as specified on the applicable master drawing. If a test voltage of the printed wiring board is not specified on
the applicable master drawing, the test voltage shall be the maximum rated voltage of the net being tested. If no
maximum rated voltage is specified, the minimum test voltage shall be 40 volts.
A.4.8.5.3
A.4.8.5.3 Dielectric withstanding voltage (see A.3.7.5.3). The printed wiring board test specimen shall be tested in
accordance with test method number 2.5.7 of IPC-TM-650, test condition B. The following details and exceptions
apply:
Test specimen: The test specimen shall be as identified in tables AIl or AV and shall been subjected to
a.
the moisture and insulation resistance test.
b.
Test specimen preparation: This portion of the test shall be skipped.
c.
Points of application: The dielectric withstanding voltage shall be applied between all common portions of
each conductor pattern and all adjacent common portions of each conductor pattern. The voltage shall be
applied between conductor patterns of each layer and the electrically isolated pattern of each adjacent layer.
37