MILPRF55110G
APPENDIX A
table AII tables AIl TABLE AII
TABLE AII. Qualification inspection.
Test specimen 1/
Requirement
Method
Notes
Inspection
Paragraph
paragraph
MTR
CTR
Visual and dimensional:
Acceptability
PWB
PWB
Microsection:
AB12
A3
As received
2/
2/
Registration (method II)
Chemical:
PWB
PWB
Cleanliness
3/
3/
Resistance to solvents
Physical:
PWB
PWB
Bow and twist
C5
J1 & J2
Plating adhesion
B2
Rework simulation
Solderability
4/
A4 & B4
AB10
Hole
D2 & D6
Surface 5/
5/
C1 & C4
Surface peel strength
A1 & B6
AB8 & AB13
Thermal stress
6/
Electrical:
7/
D3
H1, 2, & 3
Circuit continuity
E3
H1, 2, & 3
Circuit shorts
E1
8/
Dielectric withstanding voltage
Environmental:
8/
E1
Moisture and insulation resistance
D3
Thermal shock
1/
See A.4.5.2 for qualification test specimen description. MTR designates manufacturer's test routine and CTR
designates the certified test laboratories test routine. The reference "PWB" in a column means inspect all
features, holes, and patterns in zones A, B, and C of a qualification test specimen with the exception that
conductor spacing and width on test coupon E5 shall not be evaluated in zone C. For column MTR, when a test
coupon is referenced (e.g. AB10), only one of the two coupons (9 of 18 available holes) shall be inspected,
whereas for column CTR, when an individual test coupon designation is referenced (e.g. D3) means inspect the
specified test coupon. See qualification test specimen master drawing for test coupon design.
2/
Type 3 only. See A.4.8.2.4.1 for registration sample units and microsectioning details. Test coupons AB8 and
AB13 (column MTR) or A1 and B6 (column CTR) can be used to meet the diagonal corner requirement.
3/
The minimum number of samples shall be at least one sample for each solution specified by the applicable test
method (i.e., one sample for each solution required).
4/
Test coupons AB10 (36 holes from four specimens) shall be used for the MTR routine; test coupons A4 and
B4 (36 holes from two specimens) shall be used for the CTR routine.
5/
Type 1 only.
6/
Use coupon closest to the corner on MTR routine. One of the test coupons shall be microsectioned in the
qualification test specimen's length direction and the other shall be microsectioned along the qualification test
specimen's width direction.
7/
When circuit continuity verification is performed manually, the current shall not be in excess of 1.5 amperes and
the time of application shall not exceed 30 seconds.
8/
The DWV test shall be performed after the MIR test.